MKZI10시리즈(10W)

Features Industrial Standard 2"×1" Package
Ultra-wide Input Range 9-36VDC, 18-75VDC, 40-160VDC
I/O Isolation 3000VAC with Reinforced Insulation
Operating Ambient Temp. Range -40°C to +95°C
No Min. Load Requirement
Under-voltage, Overload/Voltage and Short Circuit Protection
Remote On/Off Control, Output Voltage Trim
Conducted EMI EN 55032/11 Class A Approved
Vibration and Shock/Bump Test EN 61373 Approved
Cooling, Dry & Damp Heat Test IEC/EN 60068-2-1, 2, 30 Approved
Railway EMC Standard EN 50121-3-2 Approved
Railway Certified EN 50155 (IEC60571) Approved
Fire Protection Test EN 45545-2 Approved
UL/cUL/IEC/EN 62368-1(60950-1) Safety Approval & CE Marking
제품리스트
Model NumberOutput PowerInput Voltage Range (VDC)Output Voltage (VDC)Output Current (mA)Efficiency (typ.)
MKZI10-24S0510W9-365200084%
MKZI10-24S1210W9-361283086%
MKZI10-24S1510W9-361567087%
MKZI10-24S2410W9-362441788%
MKZI10-24D1210W9-36±12±41786%
MKZI10-24D1510W9-36±15±33587%
MKZI10-48S0510W18-755200085%
MKZI10-48S1210W18-751283087%
MKZI10-48S1510W18-751567087%
MKZI10-48S2410W18-752441786%
MKZI10-48D1210W18-75±12±41789%
MKZI10-48D1510W18-75±15±33588%
MKZI10-110S0510W40-1605200082%
MKZI10-110S1210W40-1601283085%
MKZI10-110S1510W40-1601567085%
MKZI10-110S2410W40-1602441785%
MKZI10-110D1210W40-160±12±41786%
MKZI10-110D1510W40-160±15±33586%
To order the converter with heatsink, please add a suffix -HS.
To order the converter with package type A, please add a suffix A.